View Issue Details [ Jump to Notes ] | [ Issue History ] [ Print ] |
ID | Project | Category | View Status | Date Submitted | Last Update |
0022371 | ClearCenter | app-clearglass - ClearGLASS Engine | public | 2018-11-13 04:29 | 2018-11-13 08:39 |
|
Reporter | NickH | |
Assigned To | | |
Priority | normal | Severity | minor | Reproducibility | always |
Status | confirmed | Resolution | open | |
Platform | | OS | | OS Version | |
Product Version | | |
Target Version | | Fixed in Version | | |
|
Summary | 0022371: Impossible to stop ClearGLASS from the webconfig |
Description | If you navigate to Webconfig > System > Management > ClearGLASS Community and click on the stop button, ClearGLASS stops but then restarts itself a few moments later. This is **with** Dave's updated clearglass.system unit file from clearos-updates testing
I have a feeling the stop button not stopping the new clearglass.service but doing something else. The clearglass.service is then seeing clearglass down and restarting it. If this is so, the Start/Stop button needs to be changed to just stop the clearglass.service.
A "systemctl stop clearglass.service" works fine from the command line. |
Tags | No tags attached. |
|
Attached Files | |
|